14 3 3 15 1 devices if applicable class iii system.
Sprinkler systems for all strip retail centers multiple tenant buildings speculative warehouses or any other.
901 4 6 pump and riser room size.
Sprinkler riser rooms shall be located on an outside wall at grade with direct exterior access.
901 4 6 pump and riser room size.
Into the fire equipment room.
Fire pump and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary for the installation as defi ned by the manufacturer with suffi cient working room around the stationary equipment.
The fire equipment room shall be used for fire protection equipment and controls only.
This room shall contain sprinkler control valves sprinkler backflow assembly unless prohibited by the water purveyor fire pump and associated components and the fire alarm.
The minimum size of the equipment room shall allow adequate firefighter access and mobility with the following minimum clearance requirements.
A system that provides 11 2 in.
Clearances around equipment to elements of permanent.
Ft with no dimension less than 6 ft and shall be large enough to accommodate maintenance and testing actives.
It is where above ground vertical supply pipes system risers connect the water supply to the fire sprinkler system s cross and or feed mains and where the system s pressure and water are monitored and controlled.
Where provided fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary for the installation as defined by the manufacturer with sufficient working space around the stationary equipment.
Where provided fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary for the installation as defined by the manufacturer with sufficient working space around the stationary equipment.
40 testing inspection and maintenance feasibility mm hose stations.
Section 901 4 6 pump and riser room size is amended to read as follows.
966 supplement 4 combination standpipe sprinkler risers listed and or approved equipment and devices departments and those trained in handling heavy fire appropriate use and limitations of pressure regulating streams.
Riser assembly shall have a minimum of 36 inches of clearance around the pipe.